new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Oct 23

Critical Evaluation of Deep Neural Networks for Wrist Fracture Detection

Wrist Fracture is the most common type of fracture with a high incidence rate. Conventional radiography (i.e. X-ray imaging) is used for wrist fracture detection routinely, but occasionally fracture delineation poses issues and an additional confirmation by computed tomography (CT) is needed for diagnosis. Recent advances in the field of Deep Learning (DL), a subfield of Artificial Intelligence (AI), have shown that wrist fracture detection can be automated using Convolutional Neural Networks. However, previous studies did not pay close attention to the difficult cases which can only be confirmed via CT imaging. In this study, we have developed and analyzed a state-of-the-art DL-based pipeline for wrist (distal radius) fracture detection -- DeepWrist, and evaluated it against one general population test set, and one challenging test set comprising only cases requiring confirmation by CT. Our results reveal that a typical state-of-the-art approach, such as DeepWrist, while having a near-perfect performance on the general independent test set, has a substantially lower performance on the challenging test set -- average precision of 0.99 (0.99-0.99) vs 0.64 (0.46-0.83), respectively. Similarly, the area under the ROC curve was of 0.99 (0.98-0.99) vs 0.84 (0.72-0.93), respectively. Our findings highlight the importance of a meticulous analysis of DL-based models before clinical use, and unearth the need for more challenging settings for testing medical AI systems.

  • 11 authors
·
Dec 4, 2020

From Clinical Intent to Clinical Model: An Autonomous Coding-Agent Framework for Clinician-driven AI Development

Clinical AI development has traditionally followed a collaborative paradigm that depends on close interaction between clinicians and specialized AI teams. This paradigm imposes a practical challenge: clinicians must repeatedly communicate and refine their requirements with AI developers before those requirements can be translated into executable model development. This iterative process is time-consuming, and even after repeated discussion, misalignment may still exist because the two sides do not fully share each other's expertise. However, autonomous coding agents may change this paradigm, raising the possibility that clinicians could develop clinical AI models independently through natural-language interaction alone. In this study, we present such an autonomous prototype for clinician-driven clinical AI development. We evaluated the system on five clinical tasks spanning dermoscopic lesion classification, melanoma-versus-nevus triage, wrist-fracture detection (including a weakly supervised variant with only 5% bounding-box annotations), and debiased pneumothorax classification on chest radiographs. Across these settings, the system consistently developed models from clinician requests and achieved promising performance. Notably, in a debiased pneumothorax classification task on chest radiographs, where chest drains can act as a major confounder, the system successfully mitigated shortcut learning and nearly halved the model's reliance on chest drains. These findings provide proof of concept that autonomous coding agents may help shift clinical AI development toward a more clinician-driven paradigm, reducing the communication overhead and dependence on specialized AI developers. Although further validation and robustness assessment are needed, this study suggests a promising path toward making clinical AI development more accessible.

  • 6 authors
·
Apr 17

Deep Rib Fracture Instance Segmentation and Classification from CT on the RibFrac Challenge

Rib fractures are a common and potentially severe injury that can be challenging and labor-intensive to detect in CT scans. While there have been efforts to address this field, the lack of large-scale annotated datasets and evaluation benchmarks has hindered the development and validation of deep learning algorithms. To address this issue, the RibFrac Challenge was introduced, providing a benchmark dataset of over 5,000 rib fractures from 660 CT scans, with voxel-level instance mask annotations and diagnosis labels for four clinical categories (buckle, nondisplaced, displaced, or segmental). The challenge includes two tracks: a detection (instance segmentation) track evaluated by an FROC-style metric and a classification track evaluated by an F1-style metric. During the MICCAI 2020 challenge period, 243 results were evaluated, and seven teams were invited to participate in the challenge summary. The analysis revealed that several top rib fracture detection solutions achieved performance comparable or even better than human experts. Nevertheless, the current rib fracture classification solutions are hardly clinically applicable, which can be an interesting area in the future. As an active benchmark and research resource, the data and online evaluation of the RibFrac Challenge are available at the challenge website. As an independent contribution, we have also extended our previous internal baseline by incorporating recent advancements in large-scale pretrained networks and point-based rib segmentation techniques. The resulting FracNet+ demonstrates competitive performance in rib fracture detection, which lays a foundation for further research and development in AI-assisted rib fracture detection and diagnosis.

  • 25 authors
·
Feb 13, 2024

RibAssist 3D: Biplanar Rib-Fracture Detection, Addressing, and Selective 3D Localization from CT-Derived Projections

Rib fractures are common and time-consuming to localize on computed tomography (CT). We ask whether fractures detected independently in two orthogonal CT-derived projections (anteroposterior and lateral) can be paired across views and triangulated into reliable 3D points at a controlled rate of false outputs, and we answer it with a staged diagnostic study. The projection geometry is exact, and given correct correspondence, localization is accurate (median 4.0 mm, 88% within 10 mm, 93.6% rib-exact). On a sealed 55-case cohort, a large share of fractures is in principle recoverable (61.1% dual-view availability, and a correct pair present in the candidate graph for 58.4% of fractures), yet the binding limitation is neither geometry nor localization but confidence-limited cross-view correspondence. A controlled detector-by-correspondence factorial attributes the operational gain to lateral-detector quality rather than the tested matching methods; retraining the lateral detector produces the first nonzero controlled-budget reconstructions. Under a deliberately conservative commitment policy, a pre-specified sealed pass promotes 15 of 601 fractures to correct 3D localizations at 0.436 false points per case (2.50% end-to-end commitment yield), and committed points are accurate (median 1.49 mm, 93% rib-exact). The low yield is a consequence of confidence-gated abstention, not of geometry or detection: the study establishes a reproducible framework for selective 3D localization and identifies cross-view correspondence as the dominant operational bottleneck.

  • 1 authors
·
Aug 9 2

FRAC-MAS: A Safe and Explainable Multi-Agent System for Fracture Diagnosis

Fracture detection and its clinical interpretability see notable improvements when deep vision models are integrated with agentic AI architectures. While deep learning models achieve high diagnostic performance, their black-box nature limits clinical adoption. We propose FRAC-MAS, an agentic AI system for automated, explainable, and safe bone fracture detection. The framework combines a stacked ensemble of four vision models with conformal prediction to produce statistically grounded differential diagnoses, while a multi-agent workflow performs independent verification, retrieves clinical guidelines, and generates patient-friendly reports. A pipeline-depth ablation study confirms that our multi-agent critic triages 86.6% of cases into a high-confidence auto-confirmed cohort while escalating uncertain cases, outperforming a single-agent baseline. Patient preference studies against Llama, MedGemma, and Gemini further demonstrate significantly more comprehensible clinical reports. These results suggest that integrating multi-agent critics with conformal guarantees enables safer radiology triage while preserving clinician oversight. More broadly, FRAC-MAS demonstrates how cooperative agentic architectures can serve as auditable, human-in-the-loop decision support systems for safety-critical healthcare. Our code is available at https://github.com/hardik1712/FRAC-MAS, and the website is available at https://frac-mas.vercel.app.

  • 7 authors
·
Aug 21

Benchmark of Segmentation Techniques for Pelvic Fracture in CT and X-ray: Summary of the PENGWIN 2024 Challenge

The segmentation of pelvic fracture fragments in CT and X-ray images is crucial for trauma diagnosis, surgical planning, and intraoperative guidance. However, accurately and efficiently delineating the bone fragments remains a significant challenge due to complex anatomy and imaging limitations. The PENGWIN challenge, organized as a MICCAI 2024 satellite event, aimed to advance automated fracture segmentation by benchmarking state-of-the-art algorithms on these complex tasks. A diverse dataset of 150 CT scans was collected from multiple clinical centers, and a large set of simulated X-ray images was generated using the DeepDRR method. Final submissions from 16 teams worldwide were evaluated under a rigorous multi-metric testing scheme. The top-performing CT algorithm achieved an average fragment-wise intersection over union (IoU) of 0.930, demonstrating satisfactory accuracy. However, in the X-ray task, the best algorithm achieved an IoU of 0.774, which is promising but not yet sufficient for intra-operative decision-making, reflecting the inherent challenges of fragment overlap in projection imaging. Beyond the quantitative evaluation, the challenge revealed methodological diversity in algorithm design. Variations in instance representation, such as primary-secondary classification versus boundary-core separation, led to differing segmentation strategies. Despite promising results, the challenge also exposed inherent uncertainties in fragment definition, particularly in cases of incomplete fractures. These findings suggest that interactive segmentation approaches, integrating human decision-making with task-relevant information, may be essential for improving model reliability and clinical applicability.

  • 36 authors
·
Dec 29, 2025

Toward quantitative fractography using convolutional neural networks

The science of fractography revolves around the correlation between topographic characteristics of the fracture surface and the mechanisms and external conditions leading to their creation. While being a topic of investigation for centuries, it has remained mostly qualitative to date. A quantitative analysis of fracture surfaces is of prime interest for both the scientific community and the industrial sector, bearing the potential for improved understanding on the mechanisms controlling the fracture process and at the same time assessing the reliability of computational models currently being used for material design. With new advances in the field of image analysis, and specifically with machine learning tools becoming more accessible and reliable, it is now feasible to automate the process of extracting meaningful information from fracture surface images. Here, we propose a method of identifying and quantifying the relative appearance of intergranular and transgranular fracture events from scanning electron microscope images. The newly proposed method is based on a convolutional neural network algorithm for semantic segmentation. The proposed method is extensively tested and evaluated against two ceramic material systems (Al_2O_3,MgAl_2O_4) and shows high prediction accuracy, despite being trained on only one material system (MgAl_2O_4). While here attention is focused on brittle fracture characteristics, the method can be easily extended to account for other fracture morphologies, such as dimples, fatigue striations, etc.

  • 3 authors
·
Aug 1, 2019

Dataset and Benchmark for Enhancing Critical Retained Foreign Object Detection

Critical retained foreign objects (RFOs), including surgical instruments like sponges and needles, pose serious patient safety risks and carry significant financial and legal implications for healthcare institutions. Detecting critical RFOs using artificial intelligence remains challenging due to their rarity and the limited availability of chest X-ray datasets that specifically feature critical RFOs cases. Existing datasets only contain non-critical RFOs, like necklace or zipper, further limiting their utility for developing clinically impactful detection algorithms. To address these limitations, we introduce "Hopkins RFOs Bench", the first and largest dataset of its kind, containing 144 chest X-ray images of critical RFO cases collected over 18 years from the Johns Hopkins Health System. Using this dataset, we benchmark several state-of-the-art object detection models, highlighting the need for enhanced detection methodologies for critical RFO cases. Recognizing data scarcity challenges, we further explore image synthetic methods to bridge this gap. We evaluate two advanced synthetic image methods, DeepDRR-RFO, a physics-based method, and RoentGen-RFO, a diffusion-based method, for creating realistic radiographs featuring critical RFOs. Our comprehensive analysis identifies the strengths and limitations of each synthetic method, providing insights into effectively utilizing synthetic data to enhance model training. The Hopkins RFOs Bench and our findings significantly advance the development of reliable, generalizable AI-driven solutions for detecting critical RFOs in clinical chest X-rays.

  • 16 authors
·
Jul 9, 2025

IMU-Bench: Benchmarking Wrist IMU Representations Across Kinematic, Semantic and Clinical Tasks

Wrist-worn inertial measurement units (IMUs) provide a common sensing modality for tasks ranging from activity and gesture recognition to pose estimation, inertial odometry and clinical motor assessment. Existing wearable benchmarks evaluate performance across multiple tasks, but leave open how supervision for one task affects transfer to others and whether these tasks benefit from a shared representation. We present IMU-Bench, a benchmark of ten tasks from eight datasets for studying IMU multi-task performance and cross-task transfer. We compare six self-supervised methods pretrained on unlabeled recorded and simulated wrist motion, evaluating classification, pose and velocity estimation, and IMU-language retrieval. We find that our masked autoencoder, InrtlWrist, achieves the best or joint-best frozen-probe performance on nine of ten tasks, and fine-tuning improves on training from scratch on nine of ten tasks, including full-body pose, odometry and retrieval. Across transfer and joint-training experiments, supervision that benefits one target can reduce performance on others, with supervised sources transferring within kinematic estimation while, under frozen probing, none approaches the pretrained encoder on language retrieval, and joint-training gains that come at a cost to the paired task. These findings distinguish broad downstream usefulness from complementary task supervision. Code, task cards and a leaderboard are publicly available.

  • 4 authors
·
Oct 13

Frame-Synchronous Hand Gesture Detection by Projected Winding Order

Gesture recognition on video is normally posed as classification: label each frame, then act on the label. That is adequate for control, where a command may be obeyed several frames late without a user noticing, and inadequate for synchronisation, where an output must be aligned to the frame on which the gesture physically occurred. We take the synchronisation problem for one common movement, the rotation of an open hand about its long axis, and show that it admits an exact solution needing no classifier, no training data and no calibration. Let s be the normalised two-dimensional cross product of the two palm edges at the wrist and the outer knuckles, under the projection the camera already performs. We prove that s factorises as k(theta)cos(theta) with |k| > 0 everywhere, so s vanishes exactly when the palm is edge-on and its sign tracks the face presented to the camera. Detection is therefore a zero crossing of one scalar, which yields an instant rather than an interval, and we prove the criterion invariant to image mirroring, hand scale and handedness, all from its algebraic form rather than from the landmark estimator. A two-handed interaction uses four fingertips as a window onto a restyled version of the same scene. We give a coverage predicate that stays correct when the hands cross, where the usual triangulation does not, and derive each free parameter of the three stylisation operators from a noise statistic rather than by inspection. Against a corpus with exact ground truth the criterion detects 95% of flips with no false positive in 240 near-miss sequences, and places each within 6.7 ms on average of the instant it occurred, a sixth of the interval at which the hand is observed, against 23.0 ms for reporting the bracketing sample. Reporting an event more finely than one samples follows from treating a gesture as the zero of a continuous quantity rather than a label.

  • 1 authors
·
Sep 6

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

  • 1 authors
·
Oct 11

Learning Human Health and Diseases from 24-hour Wrist Movement

Much of human health and function unfolds beyond the clinic, through the movements of everyday life. Wrist-worn accelerometers capture these movements continuously, yet their rich signals are often reduced to a small set of predefined behavioural summary measures. Here, we present Sensori, a self-supervised foundation model that learns general-purpose health representations directly from 24 hours of raw tri-axial wrist movement. We developed and evaluated the model across four population-based cohorts from the United Kingdom, China and the United States, comprising 122,640 participants contributing 683,617 person-days of free-living recordings. Sensori condensed each day of movement into a representation that captured diverse movement behaviours, demographic characteristics, health axes and physical function. Evaluation in independent cohorts showed that these representations generalised across populations and measurement settings without retraining. When added to common clinical covariates, Sensori significantly improved prevalent disease classification for 52 of 102 eligible conditions (median delta AUROC, 0.060; range, 0.012-0.242) and incident disease risk prediction for 26 of 87 eligible conditions (median delta Uno's C-index, 0.064; range, 0.025-0.172), with the largest gains for neurological and psychiatric disorders. These findings establish 24-hour wrist movement as a rich and scalable source of health information, with the potential to support passive health monitoring and disease prediction at population scale.

  • 24 authors
·
Aug 29

Real-time accident detection and physiological signal monitoring to enhance motorbike safety and emergency response

Rapid urbanization and improved living standards have led to a substantial increase in the number of vehicles on the road, consequently resulting in a rise in the frequency of accidents. Among these accidents, motorbike accidents pose a particularly high risk, often resulting in serious injuries or deaths. A significant number of these fatalities occur due to delayed or inadequate medical attention. To this end, we propose a novel automatic detection and notification system specifically designed for motorbike accidents. The proposed system comprises two key components: a detection system and a physiological signal monitoring system. The detection system is integrated into the helmet and consists of a microcontroller, accelerometer, GPS, GSM, and Wi-Fi modules. The physio-monitoring system incorporates a sensor for monitoring pulse rate and SpO_{2} saturation. All collected data are presented on an LCD display and wirelessly transmitted to the detection system through the microcontroller of the physiological signal monitoring system. If the accelerometer readings consistently deviate from the specified threshold decided through extensive experimentation, the system identifies the event as an accident and transmits the victim's information -- including the GPS location, pulse rate, and SpO_{2} saturation rate -- to the designated emergency contacts. Preliminary results demonstrate the efficacy of the proposed system in accurately detecting motorbike accidents and promptly alerting emergency contacts. We firmly believe that the proposed system has the potential to significantly mitigate the risks associated with motorbike accidents and save lives.

  • 7 authors
·
Mar 27, 2024

RAM-H1200: A Unified Evaluation and Dataset on Hand Radiographs for Rheumatoid Arthritis

Rheumatoid arthritis (RA) assessment from hand radiographs requires multi-level analysis and modeling of anatomical structures and fine-grained local pathological changes. However, existing public resources do not support such unified multi-level analysis, often lacking full-hand coverage, fine-grained annotations, and consistent integration with clinical scoring systems. In particular, annotations that enable quantitative analysis of bone erosion (BE) remain scarce. RAM-H1200 contains 1,200 hand radiographs collected from six medical centers, with multi-level annotations including (i) whole-hand bone structure instance segmentation, (ii) pixel-level BE masks, (iii) SvdH-defined joint regions of interest, and (iv) joint-level SvdH scores for both BE and joint space narrowing (JSN). It is designed to evaluate whether models can jointly capture anatomical structure, localized erosive pathology, and clinically standardized RA severity from hand radiographs. The proposed BE masks enable, for the first time, quantitative BE analysis beyond coarse categorical grading by providing explicit spatial supervision for lesion extent and morphology. To our knowledge, RAM-H1200 is the first public large-scale benchmark that jointly supports whole-hand bone structure instance segmentation, pixel-level BE delineation, and clinically grounded joint-level SvdH scoring for both BE and JSN. Results across benchmark tasks show that anatomical modeling is substantially more mature than quantitative BE analysis: whole-hand bone segmentation achieves strong performance, whereas BE segmentation remains a major open challenge. By unifying anatomical structure modeling, quantitative lesion analysis, and clinically grounded SvdH scoring, RAM-H1200 provides a single benchmark for comprehensive RA analysis on hand radiographs.

  • 12 authors
·
May 6

A Multimodal RGB and Events Dataset for Hand Detection in First-Person View

Existing hand detection algorithms work on images and the detection rate is restricted by the frame rate of the camera. In hand detection applications for moving robotic systems, conventional cameras cause motion blur, especially in darker lighting conditions. We can leverage the use of event-based cameras which possess a high dynamic range, high temporal resolution, and low power consumption. Recent work has shown that using a stereo setup of an event-based and a frame-based camera improves detection accuracy and the bandwidth-latency tradeoff. The main bottleneck in using event-based cameras in object detection and recognition tasks is a relatively low amount of training data. In this work, we propose a methodology and an exemplary synthetic event-based hand dataset from an egocentric, first-person view perspective. The data is synthesized from the existing RGB Egohands dataset with the v2e toolbox. Parameters of the v2e toolbox are varied to provide versions of the dataset with different lighting conditions and scales. Ground truth detections are generated with a fine-tuned YOLOv8 model which is applied to the RGB images in the Egohands dataset and interpolated on the high-temporal resolution events. We use the multi-modal dataset to perform hand detection with existing object detection algorithms which use a multi-modal setup of event and RGB cameras and demonstrate performance comparable to the state-of-the-art.

  • 2 authors
·
Jun 8

Illicit object detection in X-ray imaging using deep learning techniques: A comparative evaluation

Automated X-ray inspection is crucial for efficient and unobtrusive security screening in various public settings. However, challenges such as object occlusion, variations in the physical properties of items, diversity in X-ray scanning devices, and limited training data hinder accurate and reliable detection of illicit items. Despite the large body of research in the field, reported experimental evaluations are often incomplete, with frequently conflicting outcomes. To shed light on the research landscape and facilitate further research, a systematic, detailed, and thorough comparative evaluation of recent Deep Learning (DL)-based methods for X-ray object detection is conducted. For this, a comprehensive evaluation framework is developed, composed of: a) Six recent, large-scale, and widely used public datasets for X-ray illicit item detection (OPIXray, CLCXray, SIXray, EDS, HiXray, and PIDray), b) Ten different state-of-the-art object detection schemes covering all main categories in the literature, including generic Convolutional Neural Network (CNN), custom CNN, generic transformer, and hybrid CNN-transformer architectures, and c) Various detection (mAP50 and mAP50:95) and time/computational-complexity (inference time (ms), parameter size (M), and computational load (GFLOPS)) metrics. A thorough analysis of the results leads to critical observations and insights, emphasizing key aspects such as: a) Overall behavior of the object detection schemes, b) Object-level detection performance, c) Dataset-specific observations, and d) Time efficiency and computational complexity analysis. To support reproducibility of the reported experimental results, the evaluation code and model weights are made publicly available at https://github.com/jgenc/xray-comparative-evaluation.

  • 8 authors
·
Jul 23, 2025

SCOPE-MRI: Bankart Lesion Detection as a Case Study in Data Curation and Deep Learning for Challenging Diagnoses

Deep learning has shown strong performance in musculoskeletal imaging, but prior work has largely targeted conditions where diagnosis is relatively straightforward. More challenging problems remain underexplored, such as detecting Bankart lesions (anterior-inferior glenoid labral tears) on standard MRIs. These lesions are difficult to diagnose due to subtle imaging features, often necessitating invasive MRI arthrograms (MRAs). We introduce ScopeMRI, the first publicly available, expert-annotated dataset for shoulder pathologies, and present a deep learning framework for Bankart lesion detection on both standard MRIs and MRAs. ScopeMRI contains shoulder MRIs from patients who underwent arthroscopy, providing ground-truth labels from intraoperative findings, the diagnostic gold standard. Separate models were trained for MRIs and MRAs using CNN- and transformer-based architectures, with predictions ensembled across multiple imaging planes. Our models achieved radiologist-level performance, with accuracy on standard MRIs surpassing radiologists interpreting MRAs. External validation on independent hospital data demonstrated initial generalizability across imaging protocols. By releasing ScopeMRI and a modular codebase for training and evaluation, we aim to accelerate research in musculoskeletal imaging and foster development of datasets and models that address clinically challenging diagnostic tasks.

  • 7 authors
·
Apr 29, 2025

Towards energy-insensitive and robust neutron/gamma classification: A learning-based frequency-domain parametric approach

Neutron/gamma discrimination has been intensively researched in recent years, due to its unique scientific value and widespread applications. With the advancement of detection materials and algorithms, nowadays we can achieve fairly good discrimination. However, further improvements rely on better utilization of detector raw signals, especially energy-independent pulse characteristics. We begin by discussing why figure-of-merit (FoM) is not a comprehensive criterion for high-precision neutron/gamma discriminators, and proposing a new evaluation method based on adversarial sampling. Inspired by frequency-domain analysis in existing literature, parametric linear/nonlinear models with minimum complexity are created, upon the discrete spectrum, with tunable parameters just as neural networks. We train the models on an open-source neutron/gamma dataset (CLYC crystals with silicon photomultipliers) preprocessed by charge normalization to discover and exploit energy-independent features. The performance is evaluated on different sampling rates and noise levels, in comparison with the frequency classification index and conventional methods. The frequency-domain parametric models show higher accuracy and better adaptability to variations of data integrity than other discriminators. The proposed method is also promising for online inference on economical hardware and portable devices.

  • 4 authors
·
May 26, 2025

THOR: Thermal-guided Hand-Object Reasoning via Adaptive Vision Sampling

Wearable cameras are increasingly used as an observational and interventional tool for human behaviors by providing detailed visual data of hand-related activities. This data can be leveraged to facilitate memory recall for logging of behavior or timely interventions aimed at improving health. However, continuous processing of RGB images from these cameras consumes significant power impacting battery lifetime, generates a large volume of unnecessary video data for post-processing, raises privacy concerns, and requires substantial computational resources for real-time analysis. We introduce THOR, a real-time adaptive spatio-temporal RGB frame sampling method that leverages thermal sensing to capture hand-object patches and classify them in real-time. We use low-resolution thermal camera data to identify moments when a person switches from one hand-related activity to another, and adjust the RGB frame sampling rate by increasing it during activity transitions and reducing it during periods of sustained activity. Additionally, we use the thermal cues from the hand to localize the region of interest (i.e., the hand-object interaction) in each RGB frame, allowing the system to crop and process only the necessary part of the image for activity recognition. We develop a wearable device to validate our method through an in-the-wild study with 14 participants and over 30 activities, and further evaluate it on Ego4D (923 participants across 9 countries, totaling 3,670 hours of video). Our results show that using only 3% of the original RGB video data, our method captures all the activity segments, and achieves hand-related activity recognition F1-score (95%) comparable to using the entire RGB video (94%). Our work provides a more practical path for the longitudinal use of wearable cameras to monitor hand-related activities and health-risk behaviors in real time.

  • 6 authors
·
Jul 7, 2025

Multi-Class 3D Object Detection Within Volumetric 3D Computed Tomography Baggage Security Screening Imagery

Automatic detection of prohibited objects within passenger baggage is important for aviation security. X-ray Computed Tomography (CT) based 3D imaging is widely used in airports for aviation security screening whilst prior work on automatic prohibited item detection focus primarily on 2D X-ray imagery. These works have proven the possibility of extending deep convolutional neural networks (CNN) based automatic prohibited item detection from 2D X-ray imagery to volumetric 3D CT baggage security screening imagery. However, previous work on 3D object detection in baggage security screening imagery focused on the detection of one specific type of objects (e.g., either {\it bottles} or {\it handguns}). As a result, multiple models are needed if more than one type of prohibited item is required to be detected in practice. In this paper, we consider the detection of multiple object categories of interest using one unified framework. To this end, we formulate a more challenging multi-class 3D object detection problem within 3D CT imagery and propose a viable solution (3D RetinaNet) to tackle this problem. To enhance the performance of detection we investigate a variety of strategies including data augmentation and varying backbone networks. Experimentation carried out to provide both quantitative and qualitative evaluations of the proposed approach to multi-class 3D object detection within 3D CT baggage security screening imagery. Experimental results demonstrate the combination of the 3D RetinaNet and a series of favorable strategies can achieve a mean Average Precision (mAP) of 65.3\% over five object classes (i.e. {\it bottles, handguns, binoculars, glock frames, iPods}). The overall performance is affected by the poor performance on {\it glock frames} and {\it iPods} due to the lack of data and their resemblance with the baggage clutter.

  • 3 authors
·
Aug 2, 2020

Calculation of Femur Caput Collum Diaphyseal angle for X-Rays images using Semantic Segmentation

This paper investigates the use of deep learning approaches to estimate the femur caput-collum-diaphyseal (CCD) angle from X-ray images. The CCD angle is an important measurement in the diagnosis of hip problems, and correct prediction can help in the planning of surgical procedures. Manual measurement of this angle, on the other hand, can be time-intensive and vulnerable to inter-observer variability. In this paper, we present a deep-learning algorithm that can reliably estimate the femur CCD angle from X-ray images. To train and test the performance of our model, we employed an X-ray image dataset with associated femur CCD angle measurements. Furthermore, we built a prototype to display the resulting predictions and to allow the user to interact with the predictions. As this is happening in a sterile setting during surgery, we expanded our interface to the possibility of being used only by voice commands. Our results show that our deep learning model predicts the femur CCD angle on X-ray images with great accuracy, with a mean absolute error of 4.3 degrees on the left femur and 4.9 degrees on the right femur on the test dataset. Our results suggest that deep learning has the potential to give a more efficient and accurate technique for predicting the femur CCD angle, which might have substantial therapeutic implications for the diagnosis and management of hip problems.

  • 4 authors
·
Apr 25, 2024

hSDB-instrument: Instrument Localization Database for Laparoscopic and Robotic Surgeries

Automated surgical instrument localization is an important technology to understand the surgical process and in order to analyze them to provide meaningful guidance during surgery or surgical index after surgery to the surgeon. We introduce a new dataset that reflects the kinematic characteristics of surgical instruments for automated surgical instrument localization of surgical videos. The hSDB(hutom Surgery DataBase)-instrument dataset consists of instrument localization information from 24 cases of laparoscopic cholecystecomy and 24 cases of robotic gastrectomy. Localization information for all instruments is provided in the form of a bounding box for object detection. To handle class imbalance problem between instruments, synthesized instruments modeled in Unity for 3D models are included as training data. Besides, for 3D instrument data, a polygon annotation is provided to enable instance segmentation of the tool. To reflect the kinematic characteristics of all instruments, they are annotated with head and body parts for laparoscopic instruments, and with head, wrist, and body parts for robotic instruments separately. Annotation data of assistive tools (specimen bag, needle, etc.) that are frequently used for surgery are also included. Moreover, we provide statistical information on the hSDB-instrument dataset and the baseline localization performances of the object detection networks trained by the MMDetection library and resulting analyses.

  • 12 authors
·
Oct 24, 2021

emg2pose: A Large and Diverse Benchmark for Surface Electromyographic Hand Pose Estimation

Hands are the primary means through which humans interact with the world. Reliable and always-available hand pose inference could yield new and intuitive control schemes for human-computer interactions, particularly in virtual and augmented reality. Computer vision is effective but requires one or multiple cameras and can struggle with occlusions, limited field of view, and poor lighting. Wearable wrist-based surface electromyography (sEMG) presents a promising alternative as an always-available modality sensing muscle activities that drive hand motion. However, sEMG signals are strongly dependent on user anatomy and sensor placement, and existing sEMG models have required hundreds of users and device placements to effectively generalize. To facilitate progress on sEMG pose inference, we introduce the emg2pose benchmark, the largest publicly available dataset of high-quality hand pose labels and wrist sEMG recordings. emg2pose contains 2kHz, 16 channel sEMG and pose labels from a 26-camera motion capture rig for 193 users, 370 hours, and 29 stages with diverse gestures - a scale comparable to vision-based hand pose datasets. We provide competitive baselines and challenging tasks evaluating real-world generalization scenarios: held-out users, sensor placements, and stages. emg2pose provides the machine learning community a platform for exploring complex generalization problems, holding potential to significantly enhance the development of sEMG-based human-computer interactions.

  • 14 authors
·
Dec 2, 2024

Asking a Multimodal LLM Whether Someone Fell: Zero-Shot Screening of Low-Resolution Thermal Video in a Laboratory and an Occupied Home

Thermal cameras can watch over older people living alone without capturing faces, and multimodal large language models (LLMs) can judge a short video without task-specific training. We evaluate a production multimodal LLM, Gemini 3.8 Flash at temperature 0, as the decision stage of an event-triggered fall screener, used exactly as a deployed prototype uses it: one request per short thermal clip, with its sound track when there is one, and its predecessor Gemini 3.7 Flash on the same requests. On 438 staged falls and 563 non-fall windows that we located by hand in a public 32x24 thermal dataset, the deployed request called 69% of the held-out subjects' falls (67% over all subjects; bed falls excluded) and none of 499 non-fall windows, including people lying on the floor and getting up. Over 76 h of ordinary life in an occupied room, recorded at 160x120 with sound, it called none of 395 clips a fall (95% upper bound 1.2 false alarms per day) and caught 4 of the 9 staged falls the camera could see. One cautionary sentence in the prompt ("a person who goes out of view ... is not a fall") accounted for many of the misses: removing it raised sensitivity on the held-out subjects from 69% to 83% on 3.8 Flash and from 80% to 92% on Gemini 3.7 Flash, and in the home from 4 to 9 of the 9 visible falls, with no false call in ordinary living but at the price of calling deliberate lie-downs a fall. Sensitivity collapsed at 8x6 pixels (34%); identical requests disagreed on 4% of windows; and when the model called a fall, its explanation placed it within a second of the annotated landing 99% of the time. Two conventional detectors trained on the laboratory data caught nearly every held-out laboratory fall but raised 14.2 and 23.9 false alarms per day in the home. We release the frame-level fall annotations of the public dataset and every model answer on it.

  • 2 authors
·
Oct 20

Tracing Like a Clinician: Anatomy-Guided Spatial Priors for Cephalometric Landmark Detection

Clinicians trace cephalometric radiographs following a structured anatomical workflow, yet no prior system encodes this into computation. We present a five-phase anatomy-guided pipeline producing confidence-weighted spatial priors that shape HRNet-W32 training, achieving 1.04 mm mean radial error on 25 landmarks across 1,502 radiographs from 7+ imaging devices. A training x inference prior matrix isolates the mechanism: anatomical priors maintain a 1% validation-to-test gap versus 88% without priors (1.94 mm), despite identical validation convergence. The matrix establishes that all trained models are inference-independent, the expanded architecture alone provides no benefit, random priors yield partial but unstable improvement (1.72 mm), and only image-specific anatomically correct priors produce the 1.04 mm result -- functioning as a training-time regularizer requiring no automated prior generation at deployment. Five-fold cross-validation (p=0.0015), patient-level permutation testing (p<0.0001, n=151), quantified Grad-CAM analysis (88% vs. 74% in-zone activation, p<0.001), and clinical measurement validation (skeletal classification kappa=0.79-0.84, zero Class II<->III reversals, ICC>0.95) provide converging evidence. Cross-domain experiments on echocardiography, cervical spine, and hand radiography support the hypothesis that prior effectiveness scales with the spatial entropy of the landmark distribution.

  • 2 authors
·
Jun 1

HealthiVert-GAN: A Novel Framework of Pseudo-Healthy Vertebral Image Synthesis for Interpretable Compression Fracture Grading

Osteoporotic vertebral compression fractures (VCFs) are prevalent in the elderly population, typically assessed on computed tomography (CT) scans by evaluating vertebral height loss. This assessment helps determine the fracture's impact on spinal stability and the need for surgical intervention. However, clinical data indicate that many VCFs exhibit irregular compression, complicating accurate diagnosis. While deep learning methods have shown promise in aiding VCFs screening, they often lack interpretability and sufficient sensitivity, limiting their clinical applicability. To address these challenges, we introduce a novel vertebra synthesis-height loss quantification-VCFs grading framework. Our proposed model, HealthiVert-GAN, utilizes a coarse-to-fine synthesis network designed to generate pseudo-healthy vertebral images that simulate the pre-fracture state of fractured vertebrae. This model integrates three auxiliary modules that leverage the morphology and height information of adjacent healthy vertebrae to ensure anatomical consistency. Additionally, we introduce the Relative Height Loss of Vertebrae (RHLV) as a quantification metric, which divides each vertebra into three sections to measure height loss between pre-fracture and post-fracture states, followed by fracture severity classification using a Support Vector Machine (SVM). Our approach achieves state-of-the-art classification performance on both the Verse2019 dataset and our private dataset, and it provides cross-sectional distribution maps of vertebral height loss. This practical tool enhances diagnostic sensitivity in clinical settings and assisting in surgical decision-making. Our code is available: https://github.com/zhibaishouheilab/HealthiVert-GAN.

  • 6 authors
·
Mar 7, 2025

Pixel-Level Pavement Distress Assessment Using Instance Segmentation

Automated pavement distress assessment requires more than image-level classification or coarse bounding box detection, demanding precise localization of thin, branching, and irregular cracks to achieve the geometric precision necessary for maintenance-relevant quantification. This paper presents a vision-based pavement distress analysis system based on Mask R-CNN instance segmentation and evaluates it on UWGB-StreetCrack, a custom field-collected roadway image dataset acquired with a vehicle-mounted smartphone and manually annotated with polygon labels for longitudinal cracks, transverse cracks, alligator cracks, and potholes. Five Detectron2-based Mask R-CNN backbone variants were considered under a consistent fine-tuning protocol. The best-performing model, Mask R-CNN with a ResNet-101 FPN backbone, achieved 84.23% precision, 90.04% recall, and an F1 score of 87.04% under the project-specific bounding-box matching protocol. The same model produced an aggregate predicted crack-area fraction of 2.164%, closely matching the 2.170% ground-truth crack-area fraction. To contextualize the segmentation system against a detector-oriented alternative, a CSPDarknet53-based YOLO detector was also adapted and retrained on the dataset, reaching 27.5% precision and 20.7% recall on the validation protocol. The results show that instance segmentation is a practical direction for field pavement imagery and aggregate crack-area estimation, while also exposing open challenges in annotation consistency, class imbalance, confounder rejection, and mask-level benchmarking.

  • 5 authors
·
May 24 2

Conformal Segmentation in Industrial Surface Defect Detection with Statistical Guarantees

In industrial settings, surface defects on steel can significantly compromise its service life and elevate potential safety risks. Traditional defect detection methods predominantly rely on manual inspection, which suffers from low efficiency and high costs. Although automated defect detection approaches based on Convolutional Neural Networks(e.g., Mask R-CNN) have advanced rapidly, their reliability remains challenged due to data annotation uncertainties during deep model training and overfitting issues. These limitations may lead to detection deviations when processing the given new test samples, rendering automated detection processes unreliable. To address this challenge, we first evaluate the detection model's practical performance through calibration data that satisfies the independent and identically distributed (i.i.d) condition with test data. Specifically, we define a loss function for each calibration sample to quantify detection error rates, such as the complement of recall rate and false discovery rate. Subsequently, we derive a statistically rigorous threshold based on a user-defined risk level to identify high-probability defective pixels in test images, thereby constructing prediction sets (e.g., defect regions). This methodology ensures that the expected error rate (mean error rate) on the test set remains strictly bounced by the predefined risk level. Additionally, we observe a negative correlation between the average prediction set size and the risk level on the test set, establishing a statistically rigorous metric for assessing detection model uncertainty. Furthermore, our study demonstrates robust and efficient control over the expected test set error rate across varying calibration-to-test partitioning ratios, validating the method's adaptability and operational effectiveness.

  • 2 authors
·
Apr 23, 2025

WILLIE: A Unified Framework and Benchmark for Wound Classification, Segmentation, and Localization

Chronic wound management affects over 8.2 million patients in the United States and imposes substantial clinical and economic burden. Clinical wound assessment commonly involves three coupled tasks: identifying wound type, delineating wound boundaries, and localizing the wound region for measurement and monitoring. Despite this clinical coupling, existing machine learning approaches typically address wound classification, segmentation, and localization using separate models. We present WILLIE, a unified framework and benchmark for wound classification, segmentation and localization that enables systematic evaluation of multi-task wound analysis under a common protocol. WILLIE harmonizes three public wound datasets into a shared benchmark and compares unified models across three scaling configurations against 10 single-task baselines. The best model achieves 91.88% classification accuracy, 91.41% Dice, and 96.23% AP@0.5 while producing all three outputs in a single forward pass. Beyond aggregate performance, our results show that segmentation-derived localization outperforms dedicated detection baselines in this benchmark, suggesting that box-based localization may be unnecessary for spatially coherent wound targets. Our findings highlight that effective multi-task learning in healthcare imaging depends not only on shared representations, but also on task formulation, compatibility, and benchmark design.

  • 5 authors
·
Oct 3

Face Detection in the Operating Room: Comparison of State-of-the-art Methods and a Self-supervised Approach

Purpose: Face detection is a needed component for the automatic analysis and assistance of human activities during surgical procedures. Efficient face detection algorithms can indeed help to detect and identify the persons present in the room, and also be used to automatically anonymize the data. However, current algorithms trained on natural images do not generalize well to the operating room (OR) images. In this work, we provide a comparison of state-of-the-art face detectors on OR data and also present an approach to train a face detector for the OR by exploiting non-annotated OR images. Methods: We propose a comparison of 6 state-of-the-art face detectors on clinical data using Multi-View Operating Room Faces (MVOR-Faces), a dataset of operating room images capturing real surgical activities. We then propose to use self-supervision, a domain adaptation method, for the task of face detection in the OR. The approach makes use of non-annotated images to fine-tune a state-of-the-art detector for the OR without using any human supervision. Results: The results show that the best model, namely the tiny face detector, yields an average precision of 0.536 at Intersection over Union (IoU) of 0.5. Our self-supervised model using non-annotated clinical data outperforms this result by 9.2%. Conclusion: We present the first comparison of state-of-the-art face detectors on operating room images and show that results can be significantly improved by using self-supervision on non-annotated data.

  • 4 authors
·
Nov 29, 2018

Xplainer: From X-Ray Observations to Explainable Zero-Shot Diagnosis

Automated diagnosis prediction from medical images is a valuable resource to support clinical decision-making. However, such systems usually need to be trained on large amounts of annotated data, which often is scarce in the medical domain. Zero-shot methods address this challenge by allowing a flexible adaption to new settings with different clinical findings without relying on labeled data. Further, to integrate automated diagnosis in the clinical workflow, methods should be transparent and explainable, increasing medical professionals' trust and facilitating correctness verification. In this work, we introduce Xplainer, a novel framework for explainable zero-shot diagnosis in the clinical setting. Xplainer adapts the classification-by-description approach of contrastive vision-language models to the multi-label medical diagnosis task. Specifically, instead of directly predicting a diagnosis, we prompt the model to classify the existence of descriptive observations, which a radiologist would look for on an X-Ray scan, and use the descriptor probabilities to estimate the likelihood of a diagnosis. Our model is explainable by design, as the final diagnosis prediction is directly based on the prediction of the underlying descriptors. We evaluate Xplainer on two chest X-ray datasets, CheXpert and ChestX-ray14, and demonstrate its effectiveness in improving the performance and explainability of zero-shot diagnosis. Our results suggest that Xplainer provides a more detailed understanding of the decision-making process and can be a valuable tool for clinical diagnosis.

  • 6 authors
·
Mar 23, 2023

LIBAD: A Multimodal Anomaly Detection Benchmark for Li-Ion Battery Electrode Manufacturing

Multimodal industrial anomaly detection has largely focused on discrete products using strongly correlated RGB and 3D observations, leaving continuous process manufacturing and weakly correlated sensing modalities underexplored. We introduce LIBAD, the first multimodal anomaly detection benchmark for Li-ion battery electrode manufacturing. Collected from real roll-to-roll production lines, LIBAD provides aligned double-sided visible-light imaging, high-resolution X-ray radiography, and inline-compatible low-resolution X-ray radiography. Electrode patches in LIBAD exhibit highly homogeneous material appearance, while defect evidence can be strong in one modality but weak or absent in another, resulting in pronounced cross-modal anomaly inconsistency. Benchmarks of representative methods under the inline-compatible visible-light and low-resolution X-ray setting exhibit limited transferability and consistently high false-positive rates. We therefore propose DA-Core, a memory-based method that jointly considers feature-space coverage and local density of normal features during coreset selection, allowing compact memory banks to better preserve fine-grained normal variations. With a coreset ratio of 0.05, DA-Core reduces FPR95 from 60.4% to 54.3% compared with standard farthest point sampling. At this ratio, DA-Core also outperforms the best standard coreset result (obtained at 0.20) while reducing inference time by 43.9%. These results suggest that both the data distribution of normal features and the modality relationship itself require explicit consideration when designing anomaly detection methods for process manufacturing.

  • 4 authors
·
Aug 7

On the Evaluation of Prohibited Item Classification and Detection in Volumetric 3D Computed Tomography Baggage Security Screening Imagery

X-ray Computed Tomography (CT) based 3D imaging is widely used in airports for aviation security screening whilst prior work on prohibited item detection focuses primarily on 2D X-ray imagery. In this paper, we aim to evaluate the possibility of extending the automatic prohibited item detection from 2D X-ray imagery to volumetric 3D CT baggage security screening imagery. To these ends, we take advantage of 3D Convolutional Neural Neworks (CNN) and popular object detection frameworks such as RetinaNet and Faster R-CNN in our work. As the first attempt to use 3D CNN for volumetric 3D CT baggage security screening, we first evaluate different CNN architectures on the classification of isolated prohibited item volumes and compare against traditional methods which use hand-crafted features. Subsequently, we evaluate object detection performance of different architectures on volumetric 3D CT baggage images. The results of our experiments on Bottle and Handgun datasets demonstrate that 3D CNN models can achieve comparable performance (98% true positive rate and 1.5% false positive rate) to traditional methods but require significantly less time for inference (0.014s per volume). Furthermore, the extended 3D object detection models achieve promising performance in detecting prohibited items within volumetric 3D CT baggage imagery with 76% mAP for bottles and 88% mAP for handguns, which shows both the challenge and promise of such threat detection within 3D CT X-ray security imagery.

  • 3 authors
·
Mar 26, 2020

A Multi-View Pipeline and Benchmark Dataset for 3D Hand Pose Estimation in Surgery

Purpose: Accurate 3D hand pose estimation supports surgical applications such as skill assessment, robot-assisted interventions, and geometry-aware workflow analysis. However, surgical environments pose severe challenges, including intense and localized lighting, frequent occlusions by instruments or staff, and uniform hand appearance due to gloves, combined with a scarcity of annotated datasets for reliable model training. Method: We propose a robust multi-view pipeline for 3D hand pose estimation in surgical contexts that requires no domain-specific fine-tuning and relies solely on off-the-shelf pretrained models. The pipeline integrates reliable person detection, whole-body pose estimation, and state-of-the-art 2D hand keypoint prediction on tracked hand crops, followed by a constrained 3D optimization. In addition, we introduce a novel surgical benchmark dataset comprising over 68,000 frames and 3,000 manually annotated 2D hand poses with triangulated 3D ground truth, recorded in a replica operating room under varying levels of scene complexity. Results: Quantitative experiments demonstrate that our method consistently outperforms baselines, achieving a 31% reduction in 2D mean joint error and a 76% reduction in 3D mean per-joint position error. Conclusion: Our work establishes a strong baseline for 3D hand pose estimation in surgery, providing both a training-free pipeline and a comprehensive annotated dataset to facilitate future research in surgical computer vision.

  • 11 authors
·
Jan 22

CrashSplat: 2D to 3D Vehicle Damage Segmentation in Gaussian Splatting

Automatic car damage detection has been a topic of significant interest for the auto insurance industry as it promises faster, accurate, and cost-effective damage assessments. However, few works have gone beyond 2D image analysis to leverage 3D reconstruction methods, which have the potential to provide a more comprehensive and geometrically accurate representation of the damage. Moreover, recent methods employing 3D representations for novel view synthesis, particularly 3D Gaussian Splatting (3D-GS), have demonstrated the ability to generate accurate and coherent 3D reconstructions from a limited number of views. In this work we introduce an automatic car damage detection pipeline that performs 3D damage segmentation by up-lifting 2D masks. Additionally, we propose a simple yet effective learning-free approach for single-view 3D-GS segmentation. Specifically, Gaussians are projected onto the image plane using camera parameters obtained via Structure from Motion (SfM). They are then filtered through an algorithm that utilizes Z-buffering along with a normal distribution model of depth and opacities. Through experiments we found that this method is particularly effective for challenging scenarios like car damage detection, where target objects (e.g., scratches, small dents) may only be clearly visible in a single view, making multi-view consistency approaches impractical or impossible. The code is publicly available at: https://github.com/DragosChileban/CrashSplat.

  • 3 authors
·
Sep 27, 2025

Retina U-Net: Embarrassingly Simple Exploitation of Segmentation Supervision for Medical Object Detection

The task of localizing and categorizing objects in medical images often remains formulated as a semantic segmentation problem. This approach, however, only indirectly solves the coarse localization task by predicting pixel-level scores, requiring ad-hoc heuristics when mapping back to object-level scores. State-of-the-art object detectors on the other hand, allow for individual object scoring in an end-to-end fashion, while ironically trading in the ability to exploit the full pixel-wise supervision signal. This can be particularly disadvantageous in the setting of medical image analysis, where data sets are notoriously small. In this paper, we propose Retina U-Net, a simple architecture, which naturally fuses the Retina Net one-stage detector with the U-Net architecture widely used for semantic segmentation in medical images. The proposed architecture recaptures discarded supervision signals by complementing object detection with an auxiliary task in the form of semantic segmentation without introducing the additional complexity of previously proposed two-stage detectors. We evaluate the importance of full segmentation supervision on two medical data sets, provide an in-depth analysis on a series of toy experiments and show how the corresponding performance gain grows in the limit of small data sets. Retina U-Net yields strong detection performance only reached by its more complex two-staged counterparts. Our framework including all methods implemented for operation on 2D and 3D images is available at github.com/pfjaeger/medicaldetectiontoolkit.

  • 7 authors
·
Nov 21, 2018

EvHand-FPV: Efficient Event-Based 3D Hand Tracking from First-Person View

Hand tracking holds great promise for intuitive interaction paradigms, but frame-based methods often struggle to meet the requirements of accuracy, low latency, and energy efficiency, especially in resource-constrained settings such as Extended Reality (XR) devices. Event cameras provide μs-level temporal resolution at mW-level power by asynchronously sensing brightness changes. In this work, we present EvHand-FPV, a lightweight framework for egocentric First-Person-View 3D hand tracking from a single event camera. We construct an event-based FPV dataset that couples synthetic training data with 3D labels and real event data with 2D labels for evaluation to address the scarcity of egocentric benchmarks. EvHand-FPV also introduces a wrist-based region of interest (ROI) that localizes the hand region via geometric cues, combined with an end-to-end mapping strategy that embeds ROI offsets into the network to reduce computation without explicit reconstruction, and a multi-task learning strategy with an auxiliary geometric feature head that improves representations without test-time overhead. On our real FPV test set, EvHand-FPV improves 2D-AUCp from 0.77 to 0.85 while reducing parameters from 11.2M to 1.2M by 89% and FLOPs per inference from 1.648G to 0.185G by 89%. It also maintains a competitive 3D-AUCp of 0.84 on synthetic data. These results demonstrate accurate and efficient egocentric event-based hand tracking suitable for on-device XR applications. The dataset and code are available at https://github.com/zen5x5/EvHand-FPV.

  • 4 authors
·
Sep 16, 2025

A Real-Time Bike-Pedestrian Safety System with Wide-Angle Perception and Evaluation Testbed for Urban Intersections

Collisions between cyclists and pedestrians at urban intersections remain a persistent source of injuries, yet few systems attempt real-time warnings to unequipped road users using commodity hardware. We present a prototype collision warning system that runs on a single edge device with a wide-angle fisheye camera, producing audible and visual alerts at 30\,fps. The system makes four contributions. First, we develop a calibration pipeline for ultra-wide fisheye lenses that overcomes corner-detection failure and optimizer divergence through perspective remapping and direct bundle adjustment. Second, we combine fisheye-aware object detection with a closed-form ground-plane projection via a precomputed lookup table. Third, we introduce a design-time conformance simulation with 24 scripted hazard scenarios, stochastic size-aware detection failures, and a latency sweep showing that a first-order kinematic predictor maintains the mean warning budget above the distracted-pedestrian reaction time across realistic camera latencies. Fourth, we formalize the decision layer as a separable, auditable testbench with explicit deployment gates, contestability mechanisms, and a residual risk register. Under conformance testing with fisheye localization error, the selected pipeline configuration achieves 93.3\% sensitivity and 92.3\% specificity, with a mean warning budget of 3.3\,s. The system design was informed by community-aided design workshops. Code and replication scripts are available at https://github.com/mkturkcan/bikeped.

  • 1 authors
·
Apr 17

Swin-X2S: Reconstructing 3D Shape from 2D Biplanar X-ray with Swin Transformers

The conversion from 2D X-ray to 3D shape holds significant potential for improving diagnostic efficiency and safety. However, existing reconstruction methods often rely on hand-crafted features, manual intervention, and prior knowledge, resulting in unstable shape errors and additional processing costs. In this paper, we introduce Swin-X2S, an end-to-end deep learning method for directly reconstructing 3D segmentation and labeling from 2D biplanar orthogonal X-ray images. Swin-X2S employs an encoder-decoder architecture: the encoder leverages 2D Swin Transformer for X-ray information extraction, while the decoder employs 3D convolution with cross-attention to integrate structural features from orthogonal views. A dimension-expanding module is introduced to bridge the encoder and decoder, ensuring a smooth conversion from 2D pixels to 3D voxels. We evaluate proposed method through extensive qualitative and quantitative experiments across nine publicly available datasets covering four anatomies (femur, hip, spine, and rib), with a total of 54 categories. Significant improvements over previous methods have been observed not only in the segmentation and labeling metrics but also in the clinically relevant parameters that are of primary concern in practical applications, which demonstrates the promise of Swin-X2S to provide an effective option for anatomical shape reconstruction in clinical scenarios. Code implementation is available at: https://github.com/liukuan5625/Swin-X2S.

  • 11 authors
·
Jan 10, 2025

Deep learning automates Cobb angle measurement compared with multi-expert observers

Scoliosis, a prevalent condition characterized by abnormal spinal curvature leading to deformity, requires precise assessment methods for effective diagnosis and management. The Cobb angle is a widely used scoliosis quantification method that measures the degree of curvature between the tilted vertebrae. Yet, manual measuring of Cobb angles is time-consuming and labor-intensive, fraught with significant interobserver and intraobserver variability. To address these challenges and the lack of interpretability found in certain existing automated methods, we have created fully automated software that not only precisely measures the Cobb angle but also provides clear visualizations of these measurements. This software integrates deep neural network-based spine region detection and segmentation, spine centerline identification, pinpointing the most significantly tilted vertebrae, and direct visualization of Cobb angles on the original images. Upon comparison with the assessments of 7 expert readers, our algorithm exhibited a mean deviation in Cobb angle measurements of 4.17 degrees, notably surpassing the manual approach's average intra-reader discrepancy of 5.16 degrees. The algorithm also achieved intra-class correlation coefficients (ICC) exceeding 0.96 and Pearson correlation coefficients above 0.944, reflecting robust agreement with expert assessments and superior measurement reliability. Through the comprehensive reader study and statistical analysis, we believe this algorithm not only ensures a higher consensus with expert readers but also enhances interpretability and reproducibility during assessments. It holds significant promise for clinical application, potentially aiding physicians in more accurate scoliosis assessment and diagnosis, thereby improving patient care.

  • 14 authors
·
Mar 18, 2024

AI-generated Images Challenge Visual Trust in High-risk Scenarios

Rapid advances in image generation are eroding the evidentiary value of visual content in settings where authenticity can affect public safety and personal reputation. Yet existing detection benchmarks rarely examine synthetic images in public- and individual-safety contexts, where misleading visual content may carry substantial risks. Here we introduce SafeIMG, a safety-oriented benchmark spanning 12 public- and individual-safety scenarios generated using GPT Image 2. Unlike benchmarks centred on generic imagery and image-level labels, SafeIMG evaluates not only whether detectors recognise synthetic images, but also whether their decisions reflect human-identified anomalies. To this end, SafeIMG provides human annotations that localise suspicious regions and explain local artefacts and higher-level commonsense or physical inconsistencies. We evaluate specialized synthetic-image detectors and vision-language models (VLMs), and find that neither provides reliable detection. The strongest VLM identifies only 49.5% of generated images, whereas the best specialised detector identifies 33.1%, compared with 81.7% accuracy for human evaluators. Model explanations cover only 29.8\% of human-annotated anomalies and predominantly capture local defects in text, faces and hands. Their coverage falls to 15.0% for commonsense conflicts and 12.0% for physical inconsistencies, while detection performance deteriorates further after dissemination-induced image degradation. These findings show that current detectors lack the accuracy, explanatory alignment and robustness needed to evaluate AI-generated images reliably across public- and individual-safety settings.

  • 8 authors
·
Jul 22

Power Battery Detection

Power batteries are essential components in electric vehicles, where internal structural defects can pose serious safety risks. We conduct a comprehensive study on a new task, power battery detection (PBD), which aims to localize the dense endpoints of cathode and anode plates from industrial X-ray images for quality inspection. Manual inspection is inefficient and error-prone, while traditional vision algorithms struggle with densely packed plates, low contrast, scale variation, and imaging artifacts. To address this issue and drive more attention into this meaningful task, we present PBD5K, the first large-scale benchmark for this task, consisting of 5,000 X-ray images from nine battery types with fine-grained annotations and eight types of real-world visual interference. To support scalable and consistent labeling, we develop an intelligent annotation pipeline that combines image filtering, model-assisted pre-labeling, cross-verification, and layered quality evaluation. We formulate PBD as a point-level segmentation problem and propose MDCNeXt, a model designed to extract and integrate multi-dimensional structure clues including point, line, and count information from the plate itself. To improve discrimination between plates and suppress visual interference, MDCNeXt incorporates two state space modules. The first is a prompt-filtered module that learns contrastive relationships guided by task-specific prompts. The second is a density-aware reordering module that refines segmentation in regions with high plate density. In addition, we propose a distance-adaptive mask generation strategy to provide robust supervision under varying spatial distributions of anode and cathode positions. The source code and datasets will be publicly available at https://github.com/Xiaoqi-Zhao-DLUT/X-ray-PBD{PBD5K}.

  • 13 authors
·
Aug 11, 2025

Peak-Detector: Explainable Peak Detection via Instruction-Tuned Large Language Models in Physiological Sign

Accurate peak detection across diverse cardiac physiological signals, including the Electrocardiogram (ECG), Photoplethysmogram (PPG), Ballistocardiogram (BCG), and Bodyseismography (BSG), is fundamental for cardiovascular monitoring but is often hindered by artifacts and signal variability. Conventional algorithms are typically engineered with expert knowledge for a single signal modality, limiting their generalizability. Conversely, deep learning-based methods often lack interpretability, limiting transparency for expert verification and hindering expert-computer interaction. To address these limitations, we introduce Peak-Detector, a novel framework that leverages instruction-tuned Large Language Models (LLMs) for robust, cross-modal, and explainable peak detection. A core innovation of our framework is a "peak-representation" technique that transforms time-series data into a condensed format, preserving critical event information while significantly reducing signal length. This representation provides a crucial inductive bias, guiding the LLM to reason over physiologically meaningful events rather than raw, noisy data. The model is optimized through a two-stage process: supervised fine-tuning (SFT) followed by reinforcement learning (RL) with a multi-objective reward function. The model's self-explanation capabilities are cultivated by fine-tuning on a custom-built Peak-Explanation dataset. Across four modalities-ECG, PPG, BCG, and BSG-spanning seven datasets (six public benchmarks plus one real-world cohort), Peak-Detector demonstrates strong cross-modal performance, achieving best or tied-best detection under clinically relevant temporal tolerance. Beyond accuracy, the generated rationales surface failure modes and support verification and error analysis.

  • 13 authors
·
May 14

Towards a Safer and Sustainable Manufacturing Process: Material classification in Laser Cutting Using Deep Learning

Laser cutting is a widely adopted technology in material processing across various industries, but it generates a significant amount of dust, smoke, and aerosols during operation, posing a risk to both the environment and workers' health. Speckle sensing has emerged as a promising method to monitor the cutting process and identify material types in real-time. This paper proposes a material classification technique using a speckle pattern of the material's surface based on deep learning to monitor and control the laser cutting process. The proposed method involves training a convolutional neural network (CNN) on a dataset of laser speckle patterns to recognize distinct material types for safe and efficient cutting. Previous methods for material classification using speckle sensing may face issues when the color of the laser used to produce the speckle pattern is changed. Experiments conducted in this study demonstrate that the proposed method achieves high accuracy in material classification, even when the laser color is changed. The model achieved an accuracy of 98.30 % on the training set and 96.88% on the validation set. Furthermore, the model was evaluated on a set of 3000 new images for 30 different materials, achieving an F1-score of 0.9643. The proposed method provides a robust and accurate solution for material-aware laser cutting using speckle sensing.

  • 3 authors
·
Nov 19, 2025

A Systematic Review of Deep Learning-based Research on Radiology Report Generation

Radiology report generation (RRG) aims to automatically generate free-text descriptions from clinical radiographs, e.g., chest X-Ray images. RRG plays an essential role in promoting clinical automation and presents significant help to provide practical assistance for inexperienced doctors and alleviate radiologists' workloads. Therefore, consider these meaningful potentials, research on RRG is experiencing explosive growth in the past half-decade, especially with the rapid development of deep learning approaches. Existing studies perform RRG from the perspective of enhancing different modalities, provide insights on optimizing the report generation process with elaborated features from both visual and textual information, and further facilitate RRG with the cross-modal interactions among them. In this paper, we present a comprehensive review of deep learning-based RRG from various perspectives. Specifically, we firstly cover pivotal RRG approaches based on the task-specific features of radiographs, reports, and the cross-modal relations between them, and then illustrate the benchmark datasets conventionally used for this task with evaluation metrics, subsequently analyze the performance of different approaches and finally offer our summary on the challenges and the trends in future directions. Overall, the goal of this paper is to serve as a tool for understanding existing literature and inspiring potential valuable research in the field of RRG.

  • 3 authors
·
Nov 23, 2023

Anatomy-Decomposed Chest Computed Tomography (CT) Projections as Scalable Supervision for Bone Suppression in Chest Radiographs

Bone overlap can obscure abnormalities in chest radiographs, while scarce paired training data limit supervised bone suppression. We address this challenge with a digitally reconstructed radiograph (DRR) framework that converts chest computed tomography (CT) into paired supervision for component suppression. A novel bone segmentation algorithm enables CT decomposition into bone, non-lung soft-tissue, and lung components, which are projected separately. Their weighted combination yields synthetic radiographs with pixel-registered component images that sum exactly to the full DRR. Models trained on these data suppress bone or lung components by predicting the target component and recovering the remainder by subtraction, transferring to real radiographs without real paired training data. As an extension, their outputs on real radiographs provide target domains for unpaired, component-wise DRR translation, reducing the appearance gap while retaining anatomical details. Across multiple public datasets, downstream detection experiments demonstrate the utility of bone suppression, with gains concentrated on abnormalities with substantial bone overlap. Compared with open-source DRR engines applied to the same CTs, our unmodified DRRs achieve comparable realism and preservation of label-relevant anatomy, while translated DRRs achieve the best Fréchet inception distance (FID), lung-field sharpness, and agreement with source-CT anatomy among the evaluated methods. Models and inference code: https://huggingface.co/qureaiorg/bone-suppression; Translated projections: https://huggingface.co/datasets/qureaiorg/ct2xr-projections.

  • 7 authors
·
Sep 20

Weighted Combination and Singular Spectrum Analysis Based Remote Photoplethysmography Pulse Extraction in Low-light Environments

Camera-based vital signs monitoring in recent years has attracted more and more researchers and the results are promising. However, a few research works focus on heart rate extraction under extremely low illumination environments. In this paper, we propose a novel framework for remote heart rate estimation under low-light conditions. This method uses singular spectrum analysis (SSA) to decompose the filtered signal into several reconstructed components. A spectral masking algorithm is utilized to refine the preliminary candidate components on the basis of a reference heart rate. The contributive components are fused into the final pulse signal. To evaluate the performance of our framework in low-light conditions, the proposed approach is tested on a large-scale multi-illumination HR dataset (named MIHR). The test results verify that the proposed method has stronger robustness to low illumination than state-of-the-art methods, effectively improving the signal-to-noise ratio and heart rate estimation precision. We further perform experiments on the PUlse RatE detection (PURE) dataset which is recorded under normal light conditions to demonstrate the generalization of our method. The experiment results show that our method can stably detect pulse rate and achieve comparative results. The proposed method pioneers a new solution to the remote heart rate estimation in low-light conditions.

  • 5 authors
·
Mar 4, 2025

Potential of Multimodal Large Language Models for Data Mining of Medical Images and Free-text Reports

Medical images and radiology reports are crucial for diagnosing medical conditions, highlighting the importance of quantitative analysis for clinical decision-making. However, the diversity and cross-source heterogeneity of these data challenge the generalizability of current data-mining methods. Multimodal large language models (MLLMs) have recently transformed many domains, significantly affecting the medical field. Notably, Gemini-Vision-series (Gemini) and GPT-4-series (GPT-4) models have epitomized a paradigm shift in Artificial General Intelligence (AGI) for computer vision, showcasing their potential in the biomedical domain. In this study, we evaluated the performance of the Gemini, GPT-4, and 4 popular large models for an exhaustive evaluation across 14 medical imaging datasets, including 5 medical imaging categories (dermatology, radiology, dentistry, ophthalmology, and endoscopy), and 3 radiology report datasets. The investigated tasks encompass disease classification, lesion segmentation, anatomical localization, disease diagnosis, report generation, and lesion detection. Our experimental results demonstrated that Gemini-series models excelled in report generation and lesion detection but faces challenges in disease classification and anatomical localization. Conversely, GPT-series models exhibited proficiency in lesion segmentation and anatomical localization but encountered difficulties in disease diagnosis and lesion detection. Additionally, both the Gemini series and GPT series contain models that have demonstrated commendable generation efficiency. While both models hold promise in reducing physician workload, alleviating pressure on limited healthcare resources, and fostering collaboration between clinical practitioners and artificial intelligence technologies, substantial enhancements and comprehensive validations remain imperative before clinical deployment.

  • 14 authors
·
Jul 8, 2024

GAZE: Grounded Agentic Zero-shot Evaluation with Viewer-Level Tools and Literature Retrieval on Rare Brain MRI

Vision-language models (VLMs) read an image and produce text in a single forward pass, whereas radiologists typically inspect an image several times and consult the literature before writing a report. We introduce GAZE (Grounded Agentic Zero-shot Evaluation), a framework that lets a medical VLM work in this iterative way by calling viewer-level tools (zoom, windowing, contrast, edge detection) and two retrieval tools backed by the U.S. National Library of Medicine (PubMed for medical literature, Open-i for radiological images), with structured outputs validated against a schema and full tool-call traces recorded for auditability. On NOVA, a benchmark of 906 brain MRI cases covering 281 rare neurological conditions, GAZE reaches 58.2 mean average precision (mAP) at intersection-over-union (IoU) 0.3 for lesion localisation and 34.9% Top-1 diagnostic accuracy under a joint protocol that scores captioning, diagnosis, and localisation from the image alone, without task-specific fine-tuning. Before any tool is used, structured prompting and schema-validated outputs already improve over the published Gemini 2.0 Flash baseline (20.2 to 29.4 mAP@0.3), so framework design is itself an experimental variable. Tool use helps rare pathologies disproportionately: the fraction of cases with IoU > 0.3 rises from 17% to 58% for diagnoses with three or fewer examples versus 25% to 68% for common conditions (geq10 cases), with gains tracking engagement (Gemini 3 Flash: Cohen's d = 0.79, 11.8 tool calls per case; Gemini 2.0 Flash: tools used in 8.2% of cases, no significant benefit). Retrieval ablations additionally reveal a model-dependent trade-off in which gains in diagnosis can coincide with losses in localisation, reinforcing the case for joint evaluation of diagnosis, localisation, and captioning in medical VLMs.

  • 3 authors
·
Apr 24

Where Does Retrieval-Based Open-Ended Evaluation Fail? Automatic Taxonomy Induction from Long-Form Medical Answer Factuality Verification

Retrieval-based factuality evaluation, where LLM-generated claims are verified against evidence from authoritative medical corpora, has become the dominant paradigm for scalable hallucination detection in high-stakes clinical settings. Despite the urgency of reliable and transparent medical fact verification, most systems measure performance with aggregate metrics like F1, which obscure where and why failures occur. Existing RAG diagnostics require gold answers or annotated gold evidence, neither of which exists in this regime. We introduce two comprehensive taxonomies, grounded in a case study on the open-ended MedExpert dataset and 3 closed-ended datasets, decomposing failures into retrieval-stage errors along five quality dimensions, and verifier-reasoning errors into six consecutive steps. We adapt an automatic pattern induction pipeline using LLM-as-Judge to label evidence quality and classify verifier reasoning errors at scale, and then stress-test our findings across 4 retrieval methods and 6 frontier verifier models. Our analysis reveals that scaling model size, adding reasoning effort, expanding to authoritative web sources, and applying medical fine-tuning do not resolve these failure modes, demonstrating that they represent fundamental limitations of the retrieve-then-verify paradigm in open-ended medical settings rather than artifacts of outdated systems. We release our code and data at https://anonymous.4open.science/r/Medical_RAG_eval-4AB5 for the full reproducibility of our results.

MedObvious: Exposing the Medical Moravec's Paradox in VLMs via Clinical Triage

Vision Language Models (VLMs) are increasingly used for tasks like medical report generation and visual question answering. However, fluent diagnostic text does not guarantee safe visual understanding. In clinical practice, interpretation begins with pre-diagnostic sanity checks: verifying that the input is valid to read (correct modality and anatomy, plausible viewpoint and orientation, and no obvious integrity violations). Existing benchmarks largely assume this step is solved, and therefore miss a critical failure mode: a model can produce plausible narratives even when the input is inconsistent or invalid. We introduce MedObvious, a 1,880-task benchmark that isolates input validation as a set-level consistency capability over small multi-panel image sets: the model must identify whether any panel violates expected coherence. MedObvious spans five progressive tiers, from basic orientation/modality mismatches to clinically motivated anatomy/viewpoint verification and triage-style cues, and includes five evaluation formats to test robustness across interfaces. Evaluating 17 different VLMs, we find that sanity checking remains unreliable: several models hallucinate anomalies on normal (negative-control) inputs, performance degrades when scaling to larger image sets, and measured accuracy varies substantially between multiple-choice and open-ended settings. These results show that pre-diagnostic verification remains unsolved for medical VLMs and should be treated as a distinct, safety-critical capability before deployment.

  • 8 authors
·
Mar 23

ConvNets for Counting: Object Detection of Transient Phenomena in Steelpan Drums

We train an object detector built from convolutional neural networks to count interference fringes in elliptical antinode regions in frames of high-speed video recordings of transient oscillations in Caribbean steelpan drums illuminated by electronic speckle pattern interferometry (ESPI). The annotations provided by our model aim to contribute to the understanding of time-dependent behavior in such drums by tracking the development of sympathetic vibration modes. The system is trained on a dataset of crowdsourced human-annotated images obtained from the Zooniverse Steelpan Vibrations Project. Due to the small number of human-annotated images and the ambiguity of the annotation task, we also evaluate the model on a large corpus of synthetic images whose properties have been matched to the real images by style transfer using a Generative Adversarial Network. Applying the model to thousands of unlabeled video frames, we measure oscillations consistent with audio recordings of these drum strikes. One unanticipated result is that sympathetic oscillations of higher-octave notes significantly precede the rise in sound intensity of the corresponding second harmonic tones; the mechanism responsible for this remains unidentified. This paper primarily concerns the development of the predictive model; further exploration of the steelpan images and deeper physical insights await its further application.

  • 2 authors
·
Jan 31, 2021

Safe-Construct: Redefining Construction Safety Violation Recognition as 3D Multi-View Engagement Task

Recognizing safety violations in construction environments is critical yet remains underexplored in computer vision. Existing models predominantly rely on 2D object detection, which fails to capture the complexities of real-world violations due to: (i) an oversimplified task formulation treating violation recognition merely as object detection, (ii) inadequate validation under realistic conditions, (iii) absence of standardized baselines, and (iv) limited scalability from the unavailability of synthetic dataset generators for diverse construction scenarios. To address these challenges, we introduce Safe-Construct, the first framework that reformulates violation recognition as a 3D multi-view engagement task, leveraging scene-level worker-object context and 3D spatial understanding. We also propose the Synthetic Indoor Construction Site Generator (SICSG) to create diverse, scalable training data, overcoming data limitations. Safe-Construct achieves a 7.6% improvement over state-of-the-art methods across four violation types. We rigorously evaluate our approach in near-realistic settings, incorporating four violations, four workers, 14 objects, and challenging conditions like occlusions (worker-object, worker-worker) and variable illumination (back-lighting, overexposure, sunlight). By integrating 3D multi-view spatial understanding and synthetic data generation, Safe-Construct sets a new benchmark for scalable and robust safety monitoring in high-risk industries. Project Website: https://Safe-Construct.github.io/Safe-Construct

EventEgoHands++: Event-based Egocentric 3D Hand Mesh Reconstruction with Real Dataset

3D hand mesh reconstruction is a challenging yet essential task for downstream applications, including human-robot interaction and AR/VR. Although conventional cameras have been widely adopted for this task, methods that rely on them struggle in low-light environments and under severe motion blur. To address these limitations, event-based cameras have recently attracted attention for their high dynamic range and high temporal resolution. However, applying event cameras to egocentric hand reconstruction remains challenging because camera wearer's motion produces dense background events that obscure hand-specific signals. Although the first egocentric event-based approach mitigates this issue using hand segmentation, its binary hand mask does not distinguish between left and right hands. As a result, the model lacks instance-level hand information and predicts both hands even when only one or neither hand is present. This limitation leads to incorrect inter-hand relationships and degraded reconstruction accuracy. In this paper, we propose EventEgoHands++, a framework for event-based 3D hand mesh reconstruction from an egocentric viewpoint. The proposed method incorporates a Hand Detector that estimates instance-level bounding boxes and masks for both the left and right hands. Moreover, we introduce Adaptive Attention, which dynamically gates the attention based on these detection results to accurately learn the spatial relationship and mutual interactions between the hands. To train and evaluate our framework, we extend the synthetic N-HOT3D dataset and newly construct EEH-R, the largest real-world event-based egocentric hand dataset to date, comprising approximately 1M annotated frames captured in environments including low-light conditions. Extensive experiments on both synthetic and real datasets demonstrate that our method consistently outperforms the baselines.

  • 4 authors
·
Sep 14 2

A Wearable Multimodal Ultrasound+Inertial System for Real-Time Virtual Reality Interaction

A-mode ultrasound (US) is a promising sensing modality for Virtual Reality (VR) interaction, as it enables the mapping of muscular activity into control commands while retaining the benefits of wearable sensing. However, existing approaches still face limitations in terms of wearability and interaction complexity, often relying on external hardware such as cameras. In this work, we propose a fully wearable multimodal interface for real-time VR-interaction, based on concurrent US and inertial (accelerometry) sensing from the forearm and upper arm. The system is built on the WULPUS platform and integrates an end-to-end software framework for real-time acquisition, visualization, and communication with a Unity-based VR environment. A multimodal learning pipeline is introduced for concurrent hand pose and forearm position estimation in 2D space. The interface is evaluated through offline and online experiments with five subjects, during the execution of three functional tasks: cylinder grasping (gross motor) and relocation, marble pinching (fine motor) and relocation, and liquid pouring. For offline experiments, we collect 5 acquisition sessions across multiple days, achieving an average inter-session accuracy across subjects of 80pm6\% for hand pose estimation and 77pm7\% for forearm position estimation. Online validation with minimal fine-tuning (5 min) demonstrates success rates of 92.0pm16.0\%, 88.0pm9.8\%, and 96.0pm8.0\% for the three tasks, respectively. With a power consumption of only 19.9~mW, our system enables more than 2.5 days of continuous use on a small 350 mAh LiPo battery without the need for recharge, enabling truly wearable, multimodal, and functionally meaningful VR interaction.

  • 6 authors
·
Sep 13

Toward Non-Invasive Diagnosis of Bankart Lesions with Deep Learning

Bankart lesions, or anterior-inferior glenoid labral tears, are diagnostically challenging on standard MRIs due to their subtle imaging features-often necessitating invasive MRI arthrograms (MRAs). This study develops deep learning (DL) models to detect Bankart lesions on both standard MRIs and MRAs, aiming to improve diagnostic accuracy and reduce reliance on MRAs. We curated a dataset of 586 shoulder MRIs (335 standard, 251 MRAs) from 558 patients who underwent arthroscopy. Ground truth labels were derived from intraoperative findings, the gold standard for Bankart lesion diagnosis. Separate DL models for MRAs and standard MRIs were trained using the Swin Transformer architecture, pre-trained on a public knee MRI dataset. Predictions from sagittal, axial, and coronal views were ensembled to optimize performance. The models were evaluated on a 20% hold-out test set (117 MRIs: 46 MRAs, 71 standard MRIs). Bankart lesions were identified in 31.9% of MRAs and 8.6% of standard MRIs. The models achieved AUCs of 0.87 (86% accuracy, 83% sensitivity, 86% specificity) and 0.90 (85% accuracy, 82% sensitivity, 86% specificity) on standard MRIs and MRAs, respectively. These results match or surpass radiologist performance on our dataset and reported literature metrics. Notably, our model's performance on non-invasive standard MRIs matched or surpassed the radiologists interpreting MRAs. This study demonstrates the feasibility of using DL to address the diagnostic challenges posed by subtle pathologies like Bankart lesions. Our models demonstrate potential to improve diagnostic confidence, reduce reliance on invasive imaging, and enhance accessibility to care.

  • 7 authors
·
Dec 9, 2024

MagCilia: A Compact Magnetociliary Tactile Sensor with 3D Force Sensing for Robotic Contact Perception and Grasping Feedback

Robotic grasping and surface exploration benefit from simultaneous measurement of normal and tangential forces and from surface information obtained through contact. Here, we present a compact magnetociliary tactile sensor (MagCilia) that combines a flexible magnetic-cilia structure with a Hall sensor for 3D force sensing. Quasi-static finite element analysis is used to investigate structural deformation and magnetic responses under multidirectional loading. To reconstruct forces from the coupled magnetic channels, we propose causal history fusion regression (CHFR), which combines current magnetic-field measurements with their recent changes. Five-fold cross-validation grouped by calibration record yields root-mean-square errors of 0.40, 0.57, and 0.69 N for Fx, Fy, and Fz, respectively, with corresponding coefficients of determination of 0.93, 0.90, and 0.92. Robotic experiments demonstrate tangential-force-guided gripper adjustment and multi-axis load monitoring under external perturbations. Frequency-domain features of the reconstructed forces distinguish six surface categories with 99.39% accuracy in three-fold cross-validation grouped by acquisition session. An online robotic demonstration additionally identifies all six tested surfaces. These results demonstrate 3D force reconstruction, grasping feedback, and surface recognition using a single compact tactile unit.

  • 10 authors
·
Oct 8

Multimodal Learning for Arcing Detection in Pantograph-Catenary Systems

The pantograph-catenary interface is essential for ensuring uninterrupted and reliable power delivery in electrified rail systems. However, electrical arcing at this interface poses serious risks, including accelerated wear of contact components, degraded system performance, and potential service disruptions. Detecting arcing events at the pantograph-catenary interface is challenging due to their transient nature, noisy operating environment, data scarcity, and the difficulty of distinguishing arcs from other similar transient phenomena. To address these challenges, we propose a novel multimodal framework that combines high-resolution image data with force measurements to more accurately and robustly detect arcing events. First, we construct two arcing detection datasets comprising synchronized visual and force measurements. One dataset is built from data provided by the Swiss Federal Railways (SBB), and the other is derived from publicly available videos of arcing events in different railway systems and synthetic force data that mimic the characteristics observed in the real dataset. Leveraging these datasets, we propose MultiDeepSAD, an extension of the DeepSAD algorithm for multiple modalities with a new loss formulation. Additionally, we introduce tailored pseudo-anomaly generation techniques specific to each data type, such as synthetic arc-like artifacts in images and simulated force irregularities, to augment training data and improve the discriminative ability of the model. Through extensive experiments and ablation studies, we demonstrate that our framework significantly outperforms baseline approaches, exhibiting enhanced sensitivity to real arcing events even under domain shifts and limited availability of real arcing observations.

  • 3 authors
·
Feb 8

A Multi-Pass Large Language Model Framework for Precise and Efficient Radiology Report Error Detection

Background: The positive predictive value (PPV) of large language model (LLM)-based proofreading for radiology reports is limited due to the low error prevalence. Purpose: To assess whether a three-pass LLM framework enhances PPV and reduces operational costs compared with baseline approaches. Materials and Methods: A retrospective analysis was performed on 1,000 consecutive radiology reports (250 each: radiography, ultrasonography, CT, MRI) from the MIMIC-III database. Two external datasets (CheXpert and Open-i) were validation sets. Three LLM frameworks were tested: (1) single-prompt detector; (2) extractor plus detector; and (3) extractor, detector, and false-positive verifier. Precision was measured by PPV and absolute true positive rate (aTPR). Efficiency was calculated from model inference charges and reviewer remuneration. Statistical significance was tested using cluster bootstrap, exact McNemar tests, and Holm-Bonferroni correction. Results: Framework PPV increased from 0.063 (95% CI, 0.036-0.101, Framework 1) to 0.079 (0.049-0.118, Framework 2), and significantly to 0.159 (0.090-0.252, Framework 3; P<.001 vs. baselines). aTPR remained stable (0.012-0.014; P>=.84). Operational costs per 1,000 reports dropped to USD 5.58 (Framework 3) from USD 9.72 (Framework 1) and USD 6.85 (Framework 2), reflecting reductions of 42.6% and 18.5%, respectively. Human-reviewed reports decreased from 192 to 88. External validation supported Framework 3's superior PPV (CheXpert 0.133, Open-i 0.105) and stable aTPR (0.007). Conclusion: A three-pass LLM framework significantly enhanced PPV and reduced operational costs, maintaining detection performance, providing an effective strategy for AI-assisted radiology report quality assurance.

  • 6 authors
·
Jun 24, 2025

Road Damage Detection Using Deep Neural Networks with Images Captured Through a Smartphone

Research on damage detection of road surfaces using image processing techniques has been actively conducted, achieving considerably high detection accuracies. Many studies only focus on the detection of the presence or absence of damage. However, in a real-world scenario, when the road managers from a governing body need to repair such damage, they need to clearly understand the type of damage in order to take effective action. In addition, in many of these previous studies, the researchers acquire their own data using different methods. Hence, there is no uniform road damage dataset available openly, leading to the absence of a benchmark for road damage detection. This study makes three contributions to address these issues. First, to the best of our knowledge, for the first time, a large-scale road damage dataset is prepared. This dataset is composed of 9,053 road damage images captured with a smartphone installed on a car, with 15,435 instances of road surface damage included in these road images. In order to generate this dataset, we cooperated with 7 municipalities in Japan and acquired road images for more than 40 hours. These images were captured in a wide variety of weather and illuminance conditions. In each image, we annotated the bounding box representing the location and type of damage. Next, we used a state-of-the-art object detection method using convolutional neural networks to train the damage detection model with our dataset, and compared the accuracy and runtime speed on both, using a GPU server and a smartphone. Finally, we demonstrate that the type of damage can be classified into eight types with high accuracy by applying the proposed object detection method. The road damage dataset, our experimental results, and the developed smartphone application used in this study are publicly available (https://github.com/sekilab/RoadDamageDetector/).

  • 5 authors
·
Feb 1, 2018

Combined Physics and Event Camera Simulator for Slip Detection

Robot manipulation is a common task in fields like industrial manufacturing. Detecting when objects slip from a robot's grasp is crucial for safe and reliable operation. Event cameras, which register pixel-level brightness changes at high temporal resolution (called ``events''), offer an elegant feature when mounted on a robot's end effector: since they only detect motion relative to their viewpoint, a properly grasped object produces no events, while a slipping object immediately triggers them. To research this feature, representative datasets are essential, both for analytic approaches and for training machine learning models. The majority of current research on slip detection with event-based data is done on real-world scenarios and manual data collection, as well as additional setups for data labeling. This can result in a significant increase in the time required for data collection, a lack of flexibility in scene setups, and a high level of complexity in the repetition of experiments. This paper presents a simulation pipeline for generating slip data using the described camera-gripper configuration in a robot arm, and demonstrates its effectiveness through initial data-driven experiments. The use of a simulator, once it is set up, has the potential to reduce the time spent on data collection, provide the ability to alter the setup at any time, simplify the process of repetition and the generation of arbitrarily large data sets. Two distinct datasets were created and validated through visual inspection and artificial neural networks (ANNs). Visual inspection confirmed photorealistic frame generation and accurate slip modeling, while three ANNs trained on this data achieved high validation accuracy and demonstrated good generalization capabilities on a separate test set, along with initial applicability to real-world data. Project page: https://github.com/tub-rip/event_slip

  • 3 authors
·
Mar 5, 2025

GraspLook: a VR-based Telemanipulation System with R-CNN-driven Augmentation of Virtual Environment

The teleoperation of robotic systems in medical applications requires stable and convenient visual feedback for the operator. The most accessible approach to delivering visual information from the remote area is using cameras to transmit a video stream from the environment. However, such systems are sensitive to the camera resolution, limited viewpoints, and cluttered environment bringing additional mental demands to the human operator. The paper proposes a novel system of teleoperation based on an augmented virtual environment (VE). The region-based convolutional neural network (R-CNN) is applied to detect the laboratory instrument and estimate its position in the remote environment to display further its digital twin in the VE, which is necessary for dexterous telemanipulation. The experimental results revealed that the developed system allows users to operate the robot smoother, which leads to a decrease in task execution time when manipulating test tubes. In addition, the participants evaluated the developed system as less mentally demanding (by 11%) and requiring less effort (by 16%) to accomplish the task than the camera-based teleoperation approach and highly assessed their performance in the augmented VE. The proposed technology can be potentially applied for conducting laboratory tests in remote areas when operating with infectious and poisonous reagents.

  • 5 authors
·
Oct 24, 2021

MissionGNN: Hierarchical Multimodal GNN-based Weakly Supervised Video Anomaly Recognition with Mission-Specific Knowledge Graph Generation

In the context of escalating safety concerns across various domains, the tasks of Video Anomaly Detection (VAD) and Video Anomaly Recognition (VAR) have emerged as critically important for applications in intelligent surveillance, evidence investigation, violence alerting, etc. These tasks, aimed at identifying and classifying deviations from normal behavior in video data, face significant challenges due to the rarity of anomalies which leads to extremely imbalanced data and the impracticality of extensive frame-level data annotation for supervised learning. This paper introduces a novel hierarchical graph neural network (GNN) based model MissionGNN that addresses these challenges by leveraging a state-of-the-art large language model and a comprehensive knowledge graph for efficient weakly supervised learning in VAR. Our approach circumvents the limitations of previous methods by avoiding heavy gradient computations on large multimodal models and enabling fully frame-level training without fixed video segmentation. Utilizing automated, mission-specific knowledge graph generation, our model provides a practical and efficient solution for real-time video analysis without the constraints of previous segmentation-based or multimodal approaches. Experimental validation on benchmark datasets demonstrates our model's performance in VAD and VAR, highlighting its potential to redefine the landscape of anomaly detection and recognition in video surveillance systems. The code is available here: https://github.com/c0510gy/MissionGNN.

  • 4 authors
·
May 22, 2025

Deep Learning Based Defect Detection for Solder Joints on Industrial X-Ray Circuit Board Images

Quality control is of vital importance during electronics production. As the methods of producing electronic circuits improve, there is an increasing chance of solder defects during assembling the printed circuit board (PCB). Many technologies have been incorporated for inspecting failed soldering, such as X-ray imaging, optical imaging, and thermal imaging. With some advanced algorithms, the new technologies are expected to control the production quality based on the digital images. However, current algorithms sometimes are not accurate enough to meet the quality control. Specialists are needed to do a follow-up checking. For automated X-ray inspection, joint of interest on the X-ray image is located by region of interest (ROI) and inspected by some algorithms. Some incorrect ROIs deteriorate the inspection algorithm. The high dimension of X-ray images and the varying sizes of image dimensions also challenge the inspection algorithms. On the other hand, recent advances on deep learning shed light on image-based tasks and are competitive to human levels. In this paper, deep learning is incorporated in X-ray imaging based quality control during PCB quality inspection. Two artificial intelligence (AI) based models are proposed and compared for joint defect detection. The noised ROI problem and the varying sizes of imaging dimension problem are addressed. The efficacy of the proposed methods are verified through experimenting on a real-world 3D X-ray dataset. By incorporating the proposed methods, specialist inspection workload is largely saved.

  • 10 authors
·
Aug 6, 2020

Controllable Multi-label Video Safety Detection via Adaptive Tversky Policy Optimization

The rapid growth of video-based social media has increased users' exposure to harmful content, creating a need for reliable automated video safety detection. Although recent Vision-Language Models (VLMs) show strong video understanding capabilities, existing harmful video detection systems face two key limitations: they typically reduce safety detection to binary classification, overlooking the inherently multi-label nature of unsafe videos, and they rely on static training objectives that do not support controllable precision-recall trade-offs, though the desired operating point may vary across moderation pipelines and unsafe categories. To address these gaps, we propose Adaptive Tversky Policy Optimization (ATPO), a reinforcement learning framework for Multi-label Video Safety Detection (Multi-VSD). ATPO introduces the Adaptive Tversky Reward (ATR), which dynamically adjusts false-positive and false-negative penalties during training to enable controllable precision-recall trade-offs. Experiments on SafeWatch-Bench and XD-Violence show that ATPO substantially improves multi-label performance, increasing the Jaccard Index from 40.66 to 75.44 on SafeWatch-Bench-Real. Moreover, ATR enables reliable steering of the precision-recall operating point, supporting deployment scenarios with heterogeneous policy requirements. Code and checkpoints are provided at https://bruceyg.github.io/ATPO-project-page/ .

  • 8 authors
·
Oct 1

Safety and accuracy follow different scaling laws in clinical large language models

Clinical LLMs are often scaled by increasing model size, context length, retrieval complexity, or inference-time compute, with the implicit expectation that higher accuracy implies safer behavior. This assumption is incomplete in medicine, where a few confident, high-risk, or evidence-contradicting errors can matter more than average benchmark performance. We introduce SaFE-Scale, a framework for measuring how clinical LLM safety changes across model scale, evidence quality, retrieval strategy, context exposure, and inference-time compute. To instantiate this framework, we introduce RadSaFE-200, a Radiology Safety-Focused Evaluation benchmark of 200 multiple-choice questions with clinician-defined clean evidence, conflict evidence, and option-level labels for high-risk error, unsafe answer, and evidence contradiction. We evaluated 34 locally deployed LLMs across six deployment conditions: closed-book prompting (zero-shot), clean evidence, conflict evidence, standard RAG, agentic RAG, and max-context prompting. Clean evidence produced the strongest improvement, increasing mean accuracy from 73.5% to 94.1%, while reducing high-risk error from 12.0% to 2.6%, contradiction from 12.7% to 2.3%, and dangerous overconfidence from 8.0% to 1.6%. Standard RAG and agentic RAG did not reproduce this safety profile: agentic RAG improved accuracy over standard RAG and reduced contradiction, but high-risk error and dangerous overconfidence remained elevated. Max-context prompting increased latency without closing the safety gap, and additional inference-time compute produced only limited gains. Worst-case analysis showed that clinically consequential errors concentrated in a small subset of questions. Clinical LLM safety is therefore not a passive consequence of scaling, but a deployment property shaped by evidence quality, retrieval design, context construction, and collective failure behavior.

  • 12 authors
·
May 4

AdverX-Ray: Ensuring X-Ray Integrity Through Frequency-Sensitive Adversarial VAEs

Ensuring the quality and integrity of medical images is crucial for maintaining diagnostic accuracy in deep learning-based Computer-Aided Diagnosis and Computer-Aided Detection (CAD) systems. Covariate shifts are subtle variations in the data distribution caused by different imaging devices or settings and can severely degrade model performance, similar to the effects of adversarial attacks. Therefore, it is vital to have a lightweight and fast method to assess the quality of these images prior to using CAD models. AdverX-Ray addresses this need by serving as an image-quality assessment layer, designed to detect covariate shifts effectively. This Adversarial Variational Autoencoder prioritizes the discriminator's role, using the suboptimal outputs of the generator as negative samples to fine-tune the discriminator's ability to identify high-frequency artifacts. Images generated by adversarial networks often exhibit severe high-frequency artifacts, guiding the discriminator to focus excessively on these components. This makes the discriminator ideal for this approach. Trained on patches from X-ray images of specific machine models, AdverX-Ray can evaluate whether a scan matches the training distribution, or if a scan from the same machine is captured under different settings. Extensive comparisons with various OOD detection methods show that AdverX-Ray significantly outperforms existing techniques, achieving a 96.2% average AUROC using only 64 random patches from an X-ray. Its lightweight and fast architecture makes it suitable for real-time applications, enhancing the reliability of medical imaging systems. The code and pretrained models are publicly available.

  • 5 authors
·
Feb 23, 2025

RAD: A Dataset and Benchmark for Real-Life Anomaly Detection with Robotic Observations

Anomaly detection is essential for robotic perception and industrial inspection, yet most benchmarks are collected under controlled conditions with fixed viewpoints and stable illumination. These settings do not reflect robotic deployment, where camera pose, lighting, and surface reflectance vary continuously. We present RAD (Realistic Anomaly Detection), a robot-captured multi-view benchmark for pose-agnostic anomaly detection. RAD contains 5,848 RGB images from 13 everyday object categories, captured from 68 viewpoints per object with a Franka robotic arm and an RGB-D camera under uncontrolled lighting. The dataset covers four realistic defect types: scratched, missing, stained, and squeezed, with pixel-level annotations for localization. We benchmark representative 2D feature-based methods, 3D reconstruction pipelines, and vision-language models under a realistic setting in which test poses are unknown. Results show a clear gap between performance on conventional benchmarks and performance on RAD. Strong 2D feature-embedding methods remain the most reliable at image-level detection, whereas 3D approaches are more competitive for pixel-level localization but remain vulnerable to reflective materials, geometric symmetry, and sparse viewpoint coverage. Vision-language models perform poorly in both classification and localization. RAD provides a challenging testbed for robust robotic inspection and highlights open problems in jointly modeling appearance, geometry, and viewpoint uncertainty. Our website and code are available at https://chang-xinhai.github.io/rad-website/.

  • 11 authors
·
Aug 2

GARF: Learning Generalizable 3D Reassembly for Real-World Fractures

3D reassembly is a challenging spatial intelligence task with broad applications across scientific domains. While large-scale synthetic datasets have fueled promising learning-based approaches, their generalizability to different domains is limited. Critically, it remains uncertain whether models trained on synthetic datasets can generalize to real-world fractures where breakage patterns are more complex. To bridge this gap, we propose GARF, a generalizable 3D reassembly framework for real-world fractures. GARF leverages fracture-aware pretraining to learn fracture features from individual fragments, with flow matching enabling precise 6-DoF alignments. At inference time, we introduce one-step preassembly, improving robustness to unseen objects and varying numbers of fractures. In collaboration with archaeologists, paleoanthropologists, and ornithologists, we curate Fractura, a diverse dataset for vision and learning communities, featuring real-world fracture types across ceramics, bones, eggshells, and lithics. Comprehensive experiments have shown our approach consistently outperforms state-of-the-art methods on both synthetic and real-world datasets, achieving 82.87\% lower rotation error and 25.15\% higher part accuracy. This sheds light on training on synthetic data to advance real-world 3D puzzle solving, demonstrating its strong generalization across unseen object shapes and diverse fracture types.

  • 12 authors
·
Apr 7, 2025

Detecting Precise Hand Touch Moments in Egocentric Video

We address the challenging task of detecting the precise moment when hands make contact with objects in egocentric videos. This frame-level detection is crucial for augmented reality, human-computer interaction, assistive technologies, and robot learning applications, where contact onset signals action initiation or completion. Temporally precise detection is particularly challenging due to subtle hand motion variations near contact, frequent occlusions, fine-grained manipulation patterns, and the inherent motion dynamics of first-person perspectives. To tackle these challenges, we propose a Hand-informed Context Enhanced module (HiCE; pronounced `high-see') that leverages spatiotemporal features from hand regions and their surrounding context through cross-attention mechanisms, learning to identify potential contact patterns. Our approach is further refined with a grasp-aware loss and soft label that emphasizes hand pose patterns and movement dynamics characteristic of touch events, enabling the model to distinguish between near-contact and actual contact frames. We also introduce TouchMoment, an egocentric dataset containing 4,021 videos and 8,456 annotated contact moments spanning over one million frames. Experiments on TouchMoment show that, under a strict evaluation criterion that counts a prediction as correct only if it falls within a two-frame tolerance of the ground-truth moment, our method achieves substantial gains and outperforms state-of-the-art event-spotting baselines by 16.91% average precision.

  • 3 authors
·
Apr 13